Vortex Flow Meter

HC design high-performance digital vortex type flowmeters for steam and all kinds of air, gases flow measuring processes.

Vortex Flow Meter

VFM60 is a powerful flow meter utilizing “Karman vortex” theory, which can meet the requirement of measuring the flow rate of various fluids such as gas, steam and liquid. The product uses the VFM60 transmitter technology, which provides with the excellent signal processing capability and enhance the vortex metering technology to a new level, which means it has lower measuring limit, better stability and accuracy. The unique dual-sensor design and special signal processing method has also ensured a better anti-vibration by eliminating the vibration signals to provide more reliable performance and lower measurement limit. The VFM60 platform is also an open platform, which means we can keep on upgrading its function according to customer’s unique requirement, and make the product a highly custom-orientation product.

Application

Steam consumption and custody transfer measurement

Compressed air measurement

Measurement of other process gases

Gas drainage in coal mines

Measurement of liquids, especially of non-conductive liquids

Specifications

Fluid to measure

Liquid, steam, gas

Nominal diameter

Wafer/Flanged(ANSI/DN/DIN/JIS):15mm~300mm(1/2"~12")
Insertion:300mm~700mm(12"~28")

Measurement rangem/s

 

DN15~25

DN32

DN40~300

Steam

8~70 m/s

4~70 m/s

2~70 m/s

Gas

8~60 m/s

4~60 m/s

2~60 m/s

Liquid

0.3~7m/s

0.3~7m/s

0.3~7m/s

Accuracy

±1% RD (insertion is 1.5%RD)
For multi-variable version: temperature ±1
,pressure:0.75% FS

Repeatability

0.3% RD

Output

[email protected] HART / RS-485

Process Temperature
Range

-40~150 ; -40~250 ; -40~350 ;

Process Pressure Limit

–0.1 MPa (–1 kg/cm2) to flange rating

Ambient Temperature Range

–40 to 85°C

Ambient Humidity

5 to 100% RH

Electrical Connection

1/2 NPT, M20 × 1.5

Materials

304 SS, 316 SS, 316L SS

Model Number

1

General model

VFM60-N

Vortex flowmeter without integral RTD and pressure sensor

Standard

 

VFM60-MV

Vortex mass flowmeter with  integral RTD and pressure sensor

Option

2

Transmitter Location

T

Integral

Standard

The standard remote cable length is 10m, if you required longer cable, please let us know

R

Remote

Option

3

Process connection

0

Insertion

Option

Insertion for DN80~700, wafer and flanged type for pipes smaller than 300mm

1

Flanged

Standard

2

Wafer

Option

3

Downsized wafer

Option

4

Fluid type

1

Liquid

Standard

If the fluid is steam, please advise if it is saturated or superheated

2

Gas

Option

3

Steam

Option

5

Wetted part material

1

OCr18Ni9(304)

Standard

For other materials, please advise your speical requirement. Any material will cause a longer production time except 304SS

2

316

Option

Q

Other

Option

6

Pressure rating

3

1.6

Standard

 

4

2.5

Option

5

4

Option

6

6.3

Option

7

10

Option

8

16

Option

7

Medium Temperature

N

T≤150

Standard

If the temperature is higher than 350 degreeC or lower than 40 degree C, please advise us to check if we can do

S

T≤250

Option

H

T≤350 (wafer or flanged)

Option

8

Transmitter

1

pulse/4~20mA

Standard

The HART signal is output though 4~20mA.

2

Battery power/pulse

Option

3

pulse/[email protected]

Option

4

pulse/RS485

Option

5

pulse/RS485 /T&P compensation

Option

7

pulse/4~20mA/T&P compensation

Option

9

Cable grinder

N

M20x1.5

Standard

 

D

1/2" NPI

Option

Q

Other

Option

 

Pipe size

xxx

xxx

 